$5.88 Buy It Now or Best Offer
free,30-Day Returns
Seller Store
() %,
Location:
Ships to: US,
Item: 155506175757
Condition:New: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is … Read moreabout the conditionNew: A brand-new, unused, unopened, undamaged item in its original packaging (where packaging is applicable). Packaging should be the same as what is found in a retail store, unless the item was packaged by the manufacturer in non-retail packaging, such as an unprinted box or plastic bag. See the seller’s listing for full details. See all condition definitionsopens in a new window or tab
Unbranded:Unbranded
UPC:Does not apply
EAN:Does not apply
eBay DC 12V Motor Controller Relay Board Forward Reverse Control Limit Start Stop Wiring Reference Diagram: General wiring: Wiring Diagram 1: Two position (switch) reciprocating (moving backward and forward in a straight line.) Wiring Diagram 2: Positive and negative start independently, each time running a single pass Wiring Diagram 3: Every time you start, run a forward and reverse rotation Product Included: 1pcs DC 12V motor forward and reverse controller Product parameters: 1 Working voltage: DC 12V (12V version) (DC power supply power ≥ motor load x3); 2 Applicable motor: brushed DC motor; 3 Maximum load current: 4.5A; 4 Signal input: active low (NPN); 5 Working modes: 9 optional modes, including momentary, self-locking, etc.; 6 Working current (excluding motor): Quiescent Current: 4MA, Forward or Reverse working current: 40MA 7 Size: 75*40*19mm; 8 Weight: 37.6 grams. Pin Description VCC : Power Supply + GND : Power Supply – M+ : Motor + M- : Motor – GND : Trigger Signal – K1 : Forward input control K2 : Reverse input control S1 : Forward limit signal S2 : Reverse limit signal This module has 4 signal input terminals, namely ”K1”, ”K2”, ”S1”, ”S2”, K1 is the forward rotation signal input terminal, K2 is the reverse rotation signal input terminal, and S2 is the forward rotation limit signal Input terminal, S2 is the reverse limit signal input terminal. The signal input source can be selected from micro switch, induction, infrared, metal, remote control and other modules, and can also be controlled by a single-chip microcomputer. Working mode: Mode 0 (default) : Self-locking mode, the signal only needs to be triggered once, and the module self-locking keeps running. – When encountering a reverse signal during forward rotation, immediately stop for 0.3 seconds and then enter reverse rotation; – The limit signal has priority, and the forward limit signal will be stopped immediately when the forward rotation is encountered; – The forward rotation cannot be started when there is a forward rotation limit signal, and the same is true for reverse rotation; – The forward rotation signal and the reverse rotation signal are valid when the low level, that is, a short-term 0V level (negative power supply), will start; – The limit signal is normally open; (For example, when the SW1 switch is closed or connected to a low level, the forward rotation cannot be started.) -Only one limit signal is valid at a time, for example: inputting two limit signals at the same time during reverse rotation cannot stop the motor rotation. Mode 1 : The automatic start version of mode 0 adds the power-on automatic start function on the basis of mode 0, that is, each time the module is powered on, it will automatically start forward rotation. This version is more suitable as a motion module between two points, and it will work automatically when the module is powered on. Mode 2: Momentary mode. When there is a forward rotation signal, the motor rotates forward; when there is a reverse rotation signal, the motor reverses; when there is no forward rotation signal and no reverse rotation signal, the motor stops; when forward rotation, if there is a forward rotation limit, it will stop forward rotation; During rotation, if there is a reverse rotation limit signal, the reverse rotation will be stopped. Removing the two limit signals will not restore the rotation, and it is necessary to re-input the rotation signal to start the forward and reverse rotation. Mode 3: The level-driven mode, similar in function to the H-bridge, operates according to the following logic: When there is a forward rotation signal and there is no signal at the forward limit, it will rotate forward; when there is a reverse signal and there is no signal at the reverse limit, it will reverse; this version is pure logic type, suitable for single-chip signal input. Pay attention to the forward rotation priority, that is, forward rotation is when both the forward and reverse input meet the conditions. Pay attention to the real-time nature of the level. For example, when there are signals at the forward and reverse input terminals at the same time, it is forward rotation. At this time, if the forward rotation signal is removed and the reverse signal is retained, it will reverse. The limit input is invalid when the motor is rotating, and the motor cannot be stopped. Mode 4: Start/Stop mode, the function is the same as mode 0, only the following function details are different: If the forward rotation has been started, input the forward rotation signal again, it will stop immediately; if the reverse rotation has been started, input the reverse rotation signal again, it will stop immediately. For example: there is a forward signal >>> forward rotation immediately; at this time, input the forward rotation signal >>> immediately stop forward rotation. Reverse the same. Mode 5: The function is the same as mode 0, only the limit signal difference is as follows: The limit signal is only valid for the current time (the leading edge is valid). For example, after starting the forward rotation, it will stop when the forward limit signal is encountered. After the stop, although the forward limit signal is still input, the forward rotation can still be started by inputting the forward rotation signal at this time. When the unidirectional start and end points are on the same motion circle, this specification is usually used, for example, press once to make a circle, and press it again to make another circle. Mode 6: One-key switch mode, the function is the same as mode 0, only the starting method is different, as follows: Forward rotation signal input, forward rotation after triggering, reverse rotation after re-triggering, and reverse rotation signal input is invalid. Input the forward rotation signal once to start the forward rotation, and stop the forward rotation when the forward limit has a signal; input the forward rotation signal again, start the reverse rotation, and stop the reverse rotation after the reverse rotation limit has a signal. Mode 7: Forward rotation when there is a forward rotation signal input, reverse rotation when there is no signal, and the reverse rotation signal input is invalid and cannot be input together with other signals. During forward rotation, the forward rotation will be stopped if there is a signal at the forward limit; during reverse rotation, the reverse rotation will be stopped if there is a signal at the reverse limit. Only one limit signal is valid at a time. for example: inputting two limit signals at the same time during reverse rotation cannot stop the motor rotation. Mode 8: Self-locking-limit normally closed mode, only the difference of the position signal, other functions are the same as mode 0. The limit signal is normally closed (for example, when there is no signal input to the forward limit, the forward rotation cannot be started, and only when the forward limit signal is input, the forward rotation can be started). Power Requirements: The DC motor governor input should be DC power. The power supply can be used but not limited to the following types: switching power supply, DC output transformer, lead-acid battery, lithium battery, solar battery and so on. The power connection wires are connected to the ”VIN” and ”GND” terminals respectively, and the positive and negative poles of the power supply cannot be reversed. The power supply voltage range is DC 11-15V (12V version), DC power requires power ≥ motor power × 3. Motor Requirements: IO56D02 is a DC motor controller, and the applied motor should be a brushed DC motor. Connect the motor connecting wires to the terminals of ”Motor+” and ”Motor-” respectively. Motor power requirements: the rated power of 12V DC motor is less than 50W, and the limit value is 100W. Payment Returns Shipping Payment We only accept payment through Paypal. Items will go to post within 1-2 business days after payment confirmed. Returns If you can’t receive the product within 2 months (60 days), please contact with us,we promise to payback 100% of your money. We ensure our products work normally before post.If the products is broken before arrival to you,all you should do is taking a photo to show us our broken product.We promise to payback 100% of your money. Shipping 1. We ship to Worldwide. 2. We only ship to confirmed PAYPAL address; your PAYPAL address must match your Shipping address. 3. Any non-received items caused by invalid address registered on PayPal are not in our full refund or replacement policy. Shipping fee has including the local handing and packaging fee. 4. All the items will be shipping within 1-2 working days after receiving the payment, except some holidays. 5. We will not be responsible for any custom delay or tax, because transit time is highly depended and provided by postal Service. 6. If you have any problem, please contact us via message, we will reply message within 1-2 working days, please wait for patient.
Frequently Asked Questions About DC 12V Motor Controller Relay Board Forward Reverse Control Limit Start Stop in My Website
easycopyco.com is the best online shopping platform where you can buy DC 12V Motor Controller Relay Board Forward Reverse Control Limit Start Stop from renowned brand(s). easycopyco.com delivers the most unique and largest selection of products from across the world especially from the US, UK and India at best prices and the fastest delivery time.
What are the best-selling DC 12V Motor Controller Relay Board Forward Reverse Control Limit Start Stop on easycopyco.com?
easycopyco.com helps you to shop online and delivers Ader Error to your doorstep. The best-selling Ader Error on easycopyco.com are: Converse Chuck Taylor All Star 70 High x Ader Error Ivory 2023 – Men’s Size 8 Converse Chuck Taylor All Star 70 High x Ader Error Ivory 2023 – Men’s Size 5.5 Converse Chuck Taylor All Star 70 Hi Ader Error |Size 10 A04455C *BRAND NEW* PUMA Cell Venom x Ader Error Men’s Size 14 Shoes New NWB Err0r White Blue Orange MENS Size 10 – PUMA Ader Error x Cell Alien White Black SHOES NEW Puma X Ader Error RS 9.8 Arthur error ball cap a1 ADERERROR × Converse Shapes Varsity Jacket Cobalt 2XL Ader Error Turquoise Wool Blend Oversize Vest Size 8M / 10W – Converse Chuck Taylor All-Star 70 Hi Ader Error Blue ✅SHIP TODAY Size 9 – Converse Chuck Taylor All Star 70 x ADER ERROR High Create Next Converse x Ader Error Chuck 70 Ox Low Top Create Next Mens Size 5 A05352c New Converse x Ader Error Chuck 70 Ox Low Top Create Next Mens Size 4 A05352c New Size 10.5 – Converse Chuck Taylor All Star 70 Hi Ader Error A04455C In Hand ADERERROR GIFT BOX & Cleaning Cloth Converse x Ader Error Chuck 70 Ox Low Top Create Next Mens Size 5.5 A05352c New Converse x Ader Error Chuck Taylor All Star 70 Ox Sneaker Size 10.5 MENS A05352C Converse Chuck Taylor All-Star 70 Hi Ader Error Mens 5.5 6 Size 7- Converse Chuck Taylor All Star 70 High x Ader Error Ivory 2023 Converse Chuck Taylor All Star 70 High x Ader Error Ivory (A04455C) – Size 4.5 PUMA x ADER ERROR NEW women’s sz 9 platform lapis blue Limited Edition PUMA RS-100 X ADER ERROR [SOLD OUT – NEW- several sizes] PUMA RS-100 X ADER ERROR [SOLD OUT – NEW- size 11] Puma x Ader Error Korea Cell Alien White Black Men Limited Used gym 370112-01 Puma RS-1 Ader Error Textile Lace Up Off White Mens Trainers US Size 11.5 Size 12 -ader error x Converse Chuck Taylor FAST SHIP Puma x Ader Error Korea Cell Alien White Black Men Limited New gym 370112-01 Mens Pullover Fleece Hoodie